Lucent-technologies PortMaster Manual do Utilizador Página 229

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 228
Using Synchronous V.25bis Connections 14-7
Configuration Steps for a Synchronous V.25bis Connection
Note – Configuring the maximum ports setting to a value higher than 0 causes the
PortMaster to dial out to a continuous location, or become available for dial-out to an
on-demand location. By configuring the maximum ports setting last, you ensure that
the PortMaster will not attempt to make a connection with a location until you have
configured all the settings for that location.
After you configure location table settings as shown in Table 14-5, enter the following
command to save the configuration:
Command> save all
For more information about configuring location table settings, refer to Chapter 8,
“Configuring Dial-Out Connections.”
Configuring the PortMaster in Miami
The PortMaster in Miami is being configured for a V.25bis dial-up synchronous
connection to the PortMaster in Boston.
Idle timer set location
miami
idle
5
Dial group set location
miami
group
1
Username set location
miami
username
miami
Telephone number set location
miami
telephone
5551212
Password set location
miami
password
anypasswd
High-water mark set location
miami
high_water
0
Maximum ports set location
miami
maxports
1
Table 14-5
Location Table Values
(Continued)
Setting Command
Vista de página 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 363 364

Comentários a estes Manuais

Sem comentários